EVALUATION OF WOOD SURFACE ROUGHNESS BY CONFOCAL MICROSCOPY

Magoss, Endre és Rozs, Richárd és Tatai, Sándor (2022) EVALUATION OF WOOD SURFACE ROUGHNESS BY CONFOCAL MICROSCOPY. WOOD RESEARCH, 67 (6). pp. 919-928. ISSN 1336-4561

[thumbnail of Evaluation-of-wood-surface-roughness-by-confocal-microscopy.pdf] Szöveg
Evaluation-of-wood-surface-roughness-by-confocal-microscopy.pdf

Download (951kB)
Hivatalos webcím (URL): https://doi.org/10.37763/wr.1336-4561/67.6.919928

Absztrakt (kivonat)

The main aim of this study is to define the usability of the confocal scanning optical microscope (CSOM) to evaluate the wood surface roughness. Therefore, systematic investigation was carried out to define the influences of CSOM on the acquisition of 2D surface roughness parameters. Mahr Perthometer was applied to get reference data to estimatetheapplicability of the CSOM. Because wood roughness parameters measured with stylus and optical methods are not always comparable a calibration method was conducted on a metal calibration etalon. After the calibration process, the roughness profiles taken with the optical and stylus units were much closer to each other and only the optical Rpkparameter was definitely higher due to artificial peaks generated by the optical system. In order to eliminate this measuringfailure, the morphological filter option of the optical apparatus may be activated. Thesurface roughness parameters were measured on planed Scotch pine samples. The planed surface plains were produced with 0.2 mm parallel offset to investigate thestructural influence of the single cutting plains. The obtained results show that the average values for Ra, Rq, Rz, Rk, and Rvkare close to each other for both measuring systems, only theoptically measured Rpkvalues must be corrected. The standard deviations, however, are systematically slightly higher for optical system. This may be explained by the higher resolution of the optical system giving more fine profile details. The earlier developed and introduced dimensionless quantities, such as Abbott ratio, are also fully comparable for both systems provided that the optically measured Rpkvalues are also correct.

Tudományterület / tudományág

műszaki tudományok > anyagtudományok és technológiák
műszaki tudományok > faipari tudományok

Kar

Nem releváns

Intézmény

Soproni Egyetem

Mű tipusa: Cikk
SWORD Depositor: Teszt Sword
Felhasználó: Csaba Horváth
A mű MTMT azonosítója: MTMT:33566517
Dátum: 24 Feb 2023 10:25
Utolsó módosítás: 24 Feb 2023 10:25
URI: http://publicatio.uni-sopron.hu/id/eprint/2597

Actions (login required)

Tétel nézet Tétel nézet

Letöltések

Letöltések havi bontásban az elmúlt egy évben